Liquid-Cooled vs Naturally Cooled Connectors

  • Liquid-Cooled EV Charging Cables and Connectors: How They Work and When to Use Them
    Liquid-Cooled EV Charging Cables and Connectors: How They Work and When to Use Them
    Oct 17, 2024
    As DC charging equipment is designed for higher currents, managing heat becomes an important consideration for both the charging connector and cable. One way to reduce electrical resistance is to use larger conductors, but this can also make the cable heavier and more difficult to handle.   Liquid cooling offers another approach. By circulating coolant through the charging assembly, it helps remove heat during high-current operation. The connector, cable, and cooling system must work together to achieve the performance required by the charger.   This guide explains how liquid-cooled charging assemblies work, how they compare with naturally cooled alternatives, and what to consider when selecting one for a DC charging project.     What Is a Liquid-Cooled EV Charging Cable and Connector? A liquid-cooled charging assembly uses circulating coolant to help manage the temperature of the charging cable and connector during DC charging. It typically works with a cooling unit and the charger’s monitoring and control system.   Liquid cooling can also be used elsewhere in an EV charging system. A charging station may use it for its power electronics, while an electric vehicle may use a separate system to regulate its battery temperature.   These cooling systems serve different components. A charger described as liquid-cooled, for example, may use liquid cooling for its power electronics without necessarily having a liquid-cooled charging cable.     Why Does High-Current Charging Generate More Heat? When electric current flows through a charging cable and connector, electrical resistance causes some energy to be released as heat. Heat is generated along the cable’s conductors and at connection points, including the contacts between the charging connector and the vehicle inlet.   For a given electrical resistance, resistive heating increases with the square of the current. Doubling the current therefore produces four times as much heat under the same conditions. How hot the assembly becomes also depends on how long the current flows, the ambient temperature, the condition of the connections, and how effectively heat is removed.   Increasing the conductor’s cross-sectional area can reduce its electrical resistance. However, a larger conductor may also increase cable size, weight, and bending stiffness. The design challenge is to meet the required current and operating conditions while keeping the cable practical to install and handle.   Liquid cooling helps address this challenge by removing heat during operation.     How Does a Liquid-Cooled EV Charging Cable Work? A liquid-cooled charging assembly contains a cooling circuit connected to a cooling unit. Coolant circulates through the charging assembly, absorbs heat from the cable and connector, and returns to the cooling unit. The cooling unit releases the absorbed heat, allowing the coolant to circulate again.   The complete system must account for heat generated along the cable and at the connector contacts. The cooling unit’s capacity, coolant flow, and operating temperature therefore need to match the requirements of the charging assembly.   Direct and Indirect Cooling Liquid-cooled charging assemblies can use different internal structures. In some designs, the coolant comes into direct contact with the conductive components it cools. In others, the coolant remains separated from the conductor or terminal, with heat passing through an intervening material or structure.   The distinction matters when selecting the coolant and materials used in the assembly. Both approaches require appropriate sealing, compatible materials, and a cooling system designed for the intended operating conditions. Their performance depends on the complete design, not simply whether contact is direct or indirect.   Monitoring and System Response A liquid-cooled connector also needs to work with the charger’s monitoring and control system. Temperature sensors can provide information about conditions in the charging assembly; the charger can then use that information as part of its control and protection strategy.   Depending on the system design, the charger may reduce current or stop charging when a monitored condition exceeds its operating limit. Sensor locations, monitored parameters, and response strategies vary between systems.     Liquid-Cooled vs. Naturally Cooled Charging Connectors Both liquid-cooled and naturally cooled connectors can be used in DC charging equipment. The difference is how they manage heat and what their integration requires.   Consideration Naturally cooled Liquid-cooled Heat management Relies on the connector and cable design to conduct and dissipate heat without an active liquid-cooling circuit. Uses circulating coolant to carry heat away from the charging assembly. Current capability Depends on the conductor size, connector design, and specified operating conditions. Depends on the assembly design and specified cooling and operating conditions. Cable handling As current requirements increase, larger conductors may affect cable size, weight, and flexibility. Active cooling can help manage heat while allowing a more manageable cable design for a given current requirement. Charger integration Does not require a liquid-cooling circuit. Requires a compatible cooling system, fluid connections, monitoring, and controls. Maintenance Requires inspection and maintenance according to the product’s instructions. Also requires attention to the cooling circuit and its components.   Neither cooling method has a single current limit that applies to every product. A naturally cooled connector can be suitable when its rated conditions meet the project’s needs. Liquid cooling becomes a consideration when the required current profile, thermal conditions, or handling requirements call for additional heat management.   Workersbee offers both naturally cooled and liquid-cooled CCS2 connectors. These products can be found in its CCS2 and Type 2 connector range.     When Should You Consider a Liquid-Cooled Charging Connector? A manufacturer developing a high-power DC charger may need a connector that carries high current under a specified charging profile while remaining manageable for drivers. A heavily used charging site may also place repeated demands on the cable throughout the day.   These scenarios make thermal performance and handling worth examining, but they do not automatically require liquid cooling. The decision starts with the current the equipment needs to deliver, how long it must deliver it, and the conditions in which the connector will operate.   Look Beyond the Charger’s Power Rating Charging power depends on both voltage and current. At the same power level, a lower voltage requires a higher current.   For example, 200 kW corresponds to approximately 500 A at 400 V, or 250 A at 800 V. These are simplified calculations; voltage and current change during an actual charging session.   A charger’s maximum power rating therefore does not, by itself, define the connector’s current requirement. The expected voltage range, current profile, and duration of high-current operation all matter when evaluating the charging assembly.   Consider How the Cable Will Be Used A cable that meets an electrical rating must also be practical for the intended installation. Its length, weight, flexibility, and routing can affect how easily a driver reaches a vehicle inlet and returns the connector after use.   For a demanding current requirement, liquid cooling may help balance thermal performance and cable handling. That benefit should be evaluated alongside the additional space, interfaces, and controls required by the cooling system.     What Should You Check When Selecting a Liquid-Cooled Connector? A liquid-cooled connector’s current rating describes only part of its operating requirements. The charging assembly and cooling unit need to be evaluated together under the conditions intended for the charger.   Current Rating and Operating Conditions Check the rated current and voltage together with the conditions specified for them. A current supported for a short period should be distinguished from one the assembly can carry continuously under stated conditions. Ambient temperature, cable length, coolant conditions, and the expected charging profile can affect whether a configuration meets the project’s needs. Comparing current ratings without comparing those conditions may give an incomplete picture.   Cooling System Compatibility The cooling unit needs to provide the flow and cooling capacity specified for the charging assembly. Its pressure range, fluid connections, operating temperatures, and coolant must also be compatible with the selected configuration.   For example, if coolant flow or heat removal is insufficient for the intended current profile, the assembly may not maintain its specified thermal performance. Conversely, a cooling unit’s power rating alone does not establish compatibility: the unit and charging assembly must be matched as a system.   The coolant also needs to be compatible with the materials it contacts. Requirements vary with the connector and cable design, so a fluid or cooling unit used with one assembly should not automatically be assumed suitable for another.   Monitoring, Leakage, and System Response Temperature monitoring provides information about the charging assembly’s operating conditions, but a sensor alone does not control the charger. The signal must be interpreted by the system, which then responds according to its protection strategy.   Cooling-circuit integrity also matters. The design, inspection, and maintenance of connections and seals help manage leakage risk. Detection methods and system responses vary, so these should be defined for the complete charger and cooling configuration.   Cable Configuration, Certification, and Service Cable length, dimensions, and handling characteristics should fit the charger layout and intended application. The applicable certification documents should also cover the selected model and configuration.   Installation instructions, inspection requirements, and replacement options are useful to review during equipment development. They help the manufacturer plan how the charging assembly will be integrated and maintained in service.     A Workersbee 800A CCS2 Liquid-Cooled Connector For manufacturers developing high-current DC charging equipment, Workersbee offers an 800A CCS2 liquid-cooled connector for high-power charging applications.   The connector uses an immersion cooling design in which the coolant comes into direct contact with the metal terminals to absorb heat. Its suitability for a project depends on the selected configuration and the conditions under which the complete charging system will operate.     Frequently Asked Questions Does every high-power DC charger need a liquid-cooled cable? No. A naturally cooled connector and cable may be suitable if they meet the required current, operating conditions, and handling needs. Liquid cooling is an option when the project requires additional heat management.   Does an 800A connector mean a vehicle will always charge at 800A? No. The connector’s rating describes its capability under specified conditions; it does not determine the current throughout a charging session. Actual current also depends on the charger, the vehicle and its battery management system, temperature, and other operating conditions.   How are coolant leaks managed in a liquid-cooled charging system? Leakage risk is addressed through cooling-circuit design, including connections and seals, as well as inspection and maintenance. The available monitoring and the charger’s response to an abnormal condition depend on the design of the complete system.     Choosing the Right Cooling Approach The right charging assembly depends on the equipment’s current requirements and the conditions in which it will operate. Evaluating the connector, cable, and cooling system together helps manufacturers identify a configuration that fits both the charger design and its intended use.   For manufacturers evaluating a liquid-cooled CCS2 solution, Workersbee can discuss connector and cable configurations based on the project’s requirements.
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
  • Attach Files
Contact us:info@workersbee.com